Managing Hub Settings in Cambrionix Connect
Introduction
Internal Hub Settings in Cambrionix Connect allow users to fine-tune the operation of their Cambrionix hubs. These settings cover a range of functionalities from naming hubs for easy identification to configuring port behaviors. Understanding and adjusting these settings can enhance the efficiency and performance of your device management. This guide provides an overview of how to access and manage these settings, including a detailed table of available settings and their default values.
Accessing Internal Hub Settings
- Select a Hub: From the main dashboard in Cambrionix Connect, navigate to the 'Hubs' section and select the hub you wish to configure.
- Access Settings: Within the hub's detailed view, locate and click on the 'Internal Hub Settings' option to view and modify the hub's configuration.
Internal Hub Settings Overview
The table below outlines the available settings within the Internal Hub Settings menu, including a description of each setting and its default value. Adjusting these settings allows for tailored management of each hub's functionality to meet specific requirements or operational preferences.
| Setting Name | Description | Default Value |
|---|---|---|
| Friendly Name | Optional "Friendly Name" set by the user. Limit of 31 characters. This name will appear in the device's system information if set. | Empty |
| Attach Threshold (mA) | The attach threshold is the device current (mA) level at which the hub can determine that a device (iPhone etc.) has been attached to a port. The attach threshold may need to be increased if the device (iPhone etc.) is connected to a Cambrionix port with a cable which includes an LED or other electronics. It may also need to be increased if you are using a device (iPhone etc.) with a 3rd party sled/holder/case (such as a barcode scanner or battery pack) which contains electronics or charging pass-through. | 10 |
| Charged Threshold (mA) | The charged threshold is used to determine if the device is probably charged. If the drawn power drops below this mark for 2 minutes, then we set a charged flag. | 100 |
| Maximum Internal Hub Temperature (°C) | Sets Maximum temperature before the shut-down of ports. | 70 |
| Port Mapping | Change the ordering of the ports from the default Sequential order. | Default |
| Default Profiles | Change the default profile for specific ports. Use 0 for default operation. | 0 |
| Ports AlwaysOn | Configure which ports to be always powered regardless of attach status. This must only be used in conjunction with a default profile. | Off |
| Sync Charge | Enable CDP* on a per port basis. | On |
| Alternative Charge Mode | Enable alternative method CDP* to support some hardware. This has no effect if Sync Charge for that port is disabled. | On |
| Display Mode | Change display mode for hubs that have extended LEDs. | Current (mA) |
| Flags | Change various flags; these are hardware specific so please see individual product user manuals for more information. | None selected |
| Stagger Delay (ms) | Introduce a delay between ports turning on when either host is detected or mode is switched to Sync. 0-9999ms | 3000 |
| Stagger Offset (ms) | An additional delay to add before starting the staggered process. 0-9999ms | 0 |
*Charging Downstream Port (CDP) being enabled means that a port is capable of transferring data
and charging the device at the same time with a higher current than just data syncing alone. With
CDP enabled the hub can supply up to 1.5A.
If you disable CDP you will receive the notification “This Hub has the Charge Downstream Port UCS
mode disabled. This could limit the maximum current seen on some ports.” This notification is to ensure you haven't turned this off by accident and can still have the highest charge available.
Adjusting Settings
To modify a setting:
- Select the Setting: Click on the setting you wish to change.
- Adjust Value: Modify the value or configuration as needed.
- Save Changes: Ensure to save your adjustments for the changes to take effect immediately.
Best Practices
- Review Defaults: Familiarise yourself with the default settings to understand the baseline configuration of your hub.
- Tailor to Needs: Adjust settings to meet the specific needs of your deployment, considering the types of devices connected and operational requirements.
- Monitor Performance: After making changes, monitor your hub's performance to ensure the adjustments have the desired effect.
Support
If you require further assistance with Internal Hub Settings or have questions about specific configurations, please consult the Cambrionix Connect User Manual or reach out to our Support team who will be glad to assist.