Skip to main content

Fan Behaviour

Your SuperSync15 has an inbuilt fan used to cool the product when internal temperatures rise above a set threshold. On power up the fan will spin for approximately a second before turning off. For more information on the temperatures that trigger the fan please see the fan properties section in the Hub Specifications.

When looking into the specifications you will see five different temperatures relating to fan speed and temperatures. Some information on how this relates to your product, please see the below table:

SettingDescription
Start Temperature (°C)The temperature at which the fan will initially turn on
50% Speed Start Temperature (°C)The temperature at which the fan will increase to 50% speed
Max Airflow Temperature (°C)The temperature at which the fan will increase to 100% speed
Drop to 50% Speed Temperature (°C)The temperature at which the fan will decrease to 50% speed
Stop Temperature (°C)The temperature at which the fan will turn off